Main
range of product TeSys D
TeSys F
range TeSys
product or component type Auxiliary contact block
auxiliary contacts operation Instantaneous
pole contact composition 1 NO
connections – terminals Screw clamp terminals 1 cable 1…2.5 mm² – cable stiffness: flexible – with cable end
Screw clamp terminals 1 cable 1…2.5 mm² – cable stiffness: flexible – without cable end
Screw clamp terminals 1 cable 1…2.5 mm² – cable stiffness: solid – with cable end
Screw clamp terminals 1 cable 1…2.5 mm² – cable stiffness: solid – without cable end
Screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: flexible – with cable end
Screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: flexible – without cable end
Screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: solid – with cable end
Screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: solid – without cable end
Complementary
mounting location Front
[Ui] rated insulation voltage 690 V – conforming to IEC 60947-5-1
600 V – certifications CSA
600 V – certifications UL
[Ue] rated operational voltage 690 V AC 25…400 Hz
[Ith] conventional free air thermal current 10 A at <= 60 °C
Irms rated making capacity 140 A at <= 690 V AC conforming to IEC 60947-5-1
250 A at <= 690 V DC conforming to IEC 60947-5-1
permissible short-time rating 100 A at 60 °C 1 s
120 A at 60 °C 500 ms
140 A at 60 °C 100 ms
protection type GG fuse <= 10 A rating according to operational current for Ue <= 690 V
associated fuse rating 10 A gG IEC 60947-5-1
mechanical durability 30 Mcycles
minimum switching current 5 mA
minimum switching voltage 17 V
non-overlap time 1.5 ms on de-energisation (no overlap between NC and NO contact)
1.5 ms on energisation (no overlap between NC and NO contact)
overlap time 1.5 ms
insulation resistance > 10 MOhm
product weight 0.02 kg
Environment
environmental characteristic Normal environment
standards BS 4794
EN 60947-5-1
IEC 60947-5-1
NF C 63-140
VDE 0660
product certifications CSA
UL
IP degree of protection IP2x conforming to VDE 0106
protective treatment TH conforming to IEC 60068
ambient air temperature for operation -5…60 °C
ambient air temperature for storage -60…80 °C
operating altitude 3000 m without derating in temperature